Sign In | Join Free | My ccnmag.com
China Xi'an Dehou Electronic Technology Co., Ltd. logo
Xi'an Dehou Electronic Technology Co., Ltd.
Xi'an Dehou Electronic Technology Co., Ltd.
Verified Supplier

4 Years

Home > RF Admittance Level Switch >

Anti Adhesion Soft Cable RF Admittance Level Switch NYSP - L864

Xi'an Dehou Electronic Technology Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

Anti Adhesion Soft Cable RF Admittance Level Switch NYSP - L864

  • 1
  • 2

Brand Name : NUOYINGJIAYE

Model Number : NYSP-L864

Certification : CE,ATEX,SIL

Place of Origin : Xi'an,Shannxi,China

MOQ : 1pcs

Price : $150~$350/pcs

Payment Terms : T/T

Supply Ability : 1000 pcs/per month

Delivery Time : 7 working days

Packaging Details : Carton, 90cm x 30cm x 30cm

Products model : NYSP-L864

Probe material : 304+PTFE(optional)

Probe length : 500mm(The length can be customized according to the site conditions)

Power supply : 24VDC,220VAC(optional)

Output relay : Double pole, double throw (DPDT) output,5A, 24V DC or 5A, 220VAC

Power loss protection : Open, close, field switchable

Time delay : 0~30s adjustable

Procedure connection : Thread/flange(optional)

Contact Now

Anti-Adhesion NYSP-L864 Soft Cable RF Admittance Level Switch

NYSP-L864 RF Admittance Level Switch Working Principle

The working principle of the radio frequency admittance level switch is based on radio frequency (RF) capacitive technology. A radio frequency is applied to the probe and, through continuous analysis, the effects caused by the surrounding environment are determined. Since all materials have a permittivity and their conductivity is different from that of air, the overall impedance reflected by the small capacitance shift changes when the probe is in contact with the material. Because the energized probe and the vessel wall form the two polar plates of the capacitor, the insulator of the probe and the surrounding air become the dielectric material, when the air (whose dielectric constant is 1.0) is replaced by any other material (the dielectric constant > 1), The capacitive effect is enhanced. Thus changing the impedance of the application. That is, the change of capacitance value causes the change of impedance. This effect is measured by the circuit and compared to a reference established by the sensitivity setting (circuit).

The correct setting of the RF admittance level switch sensitivity will affect the correct change in the sensor output. The probe's Null-KoTeTM circuit allows the measurement circuit to ignore material buildup on the probe, which would otherwise cause sensitivity failures. The Null-KoTeTM circuit is used to apply the same radio frequency potential excitation to the sensing probe. Since current cannot flow at the same potential, the Null-KoTeTM circuit interrupts the flow of current that would normally flow from the energized probe through the bulk material to the vessel wall. This measures the material around the energized probe, not the accumulated material.

NYSP-L864 RF Admittance Level Switch Technical Parameter

Typical application The length is more than 2 meters, it is installed vertically on the top and can be used as a vertical switch,can be used as coal conveyer
Products model NYSP-L864
Probe material 304+PTFE(optional)
Probe length 500mm(The length can be customized according to the site conditions)
Process temperature -40℃~+130℃
Process pressure <2.0MPa
Power supply 24VDC,220VAC(optional)
Time delay 0~30s adjustable
Procedure connection Thread/flange(optional)
Power loss protection Open, close, field switchable
Output relay Double pole, double throw (DPDT) output,5A, 24V DC or 5A, 220VAC
Protection level IP67
Explosion proof grade Exia II CT6

NYSP-L864 RF Admittance Level Switch Design Features

1.Anti-adhesion: The patented anti-adhesion circuit can eliminate false signals caused by material adhesion.

2.Strong versatility: It can be applied to the measurement of various conductive and non-conductive media, such as liquids, viscous substances, particles, powders, and fly ash.

3.Detachable probe: There is no cable connection between the controller and the probe. The controller can be removed and replaced at any time for maintenance without affecting the incoming and outgoing materials.

4.High and low temperature resistance: suitable for working environment from -184°C to 280°C, and ceramic probes for higher temperature are also available.

5.Output form: double-pole double-throw relay signal output, at the same time there is a status light to display the output status, and a delay function of 0 to 30 seconds.

6.Intelligent diagnosis: After the power is turned on, the instrument circuit automatically detects whether the working state is normal.

NYSP RF Admittance Switch Application Field
1.Hydraulic machinery: detection of lubricating oil level.
2.Constniction machinery: testing material level of cement warehouse and mixing tank material level.
3.Foundry machinery: sand level detection.
4.Environmental protection water treatment: detection of sewage liquid level.
5.Glass factory: testing quartz sand and broken glass level.
6.Chemical factory: detection of polyester, spandex, acid, alkali and other chemical materials liquid level.
7.Boiler plant: check drum water level, and other pressure vessel liquid level.
8.Flour mill: flour, wheat grain material level.
9.Feeding Plant: detection of Soybean meal level.
10.Power plant: detection of fly ash level.
11.Other applications: natural gas,juice? ketchup, etc.

Product Tags:

Anti Adhesion Admittance Level Sensor

      

Soft Cable Admittance Level Switch

      

RF Admittance Type Level Switch

      
China Anti Adhesion Soft Cable RF Admittance Level Switch NYSP - L864 wholesale

Anti Adhesion Soft Cable RF Admittance Level Switch NYSP - L864 Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Xi'an Dehou Electronic Technology Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)